Login
Contact your Sales Executive to obtain your first password.
EPCOM Certified Products
We test, inspect and restore all EPCOM products to working conditions.
Stock | Classification | Your Price |
---|
Product Specifications
- Connector Impedance 50 ohm
- Operating Frequency Band 0 – 3300 MHz
- Cable Impedance 50 ohm
- 3rd Order IMD, typical -116 dBm @ 910 MHz
- 3rd Order IMD Test Method Two +43 dBm carriers
- RF Operating Voltage, maximum (vrms) 707.00 V
- DC Test Voltage 2000 V
- Outer Contact Resistance, maximum 0.30 mOhm
- Inner Contact Resistance, maximum 2.00 mOhm
- Insulation Resistance, minimum 5000 MOhm
- Average Power 0.6 kW @ 900 MHz
- Peak Power, maximum 10.00 kW
- Insertion Loss, typical 0.05 dB
- Shielding Effectiveness -130 dB
- Interface N Male
- Body Style Straight
- Brand HELIAX® | OnePiece™
- Mounting Angle Straight
- Outer Contact Attachment Method Ring-flare
- Inner Contact Attachment Method Captivated
- Outer Contact Plating Trimetal
- Inner Contact Plating Silver
- Attachment Durability 25 cycles
- Interface Durability 500 cycles
- Interface Durability Method IEC 61169-16:9.5
- Connector Retention Tensile Force 1779 N | 400 lbf
- Connector Retention Torque 10.85 N-m | 96.00 in lb
- Insertion Force 66.72 N | 15.00 lbf
- Insertion Force Method MIL-C-39012C-3.12, 4.6.9
- Pressurizable No
- Coupling Nut Proof Torque 4.52 N-m | 40.00 in lb
- Coupling Nut Retention Force 444.82 N | 100.00 lbf
- Coupling Nut Retention Force Method MIL-C-39012C-3.25, 4.6.22
- Nominal Size 1-1/4 in
- Diameter 51.31 mm | 2.02 in
- Length 104.90 mm | 4.13 in
- Weight 608.35 g | 1.34 lb
- Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
- Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F)
- Immersion Depth 1 m
- Immersion Test Mating Unmated
- Immersion Test Method IEC 60529:2001, IP68
- Water Jetting Test Mating Unmated
- Water Jetting Test Method IEC 60529:2001, IP66
- Moisture Resistance Test Method MIL-STD-202F, Method 106F
- Mechanical Shock Test Method MIL-STD-202F, Method 213B, Test Condition C
- Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
- Vibration Test Method MIL-STD-202F, Method 204D, Test Condition B
- Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A
- Attenuation, Ambient Temperature 20 °C | 68 °F
- Average Power, Ambient Temperature 40 °C | 104 °F
- Return Loss/VSWR
- Frequency Band VSWR Return Loss (dB)
- 45–400 MHz 1.02 39.00
- 401–805 MHz 1.02 39.00
- 806–960 MHz 1.02 39.00
- 961–1709 MHz 1.03 37.00
- 1710–2170 MHz 1.03 36.00
- 2170–2399 MHz 1.04 35.00
- 2400–2700 MHz 1.04 34.00
- 2700–3500 MHz 1.05 32.00
- 3400–3600 MHz 1.07 30.00
- Agency Classification
- RoHS 2011/65/EU Compliant by Exemption
- China RoHS SJ/T 11364-2006 Above Maximum Concentration Value (MCV)